Proposed technical content for steel frame

Proposed technical content for C 140 Profile:

Wall layer structure (from outside to inside):

  • exterior facade painting
  • Optional: full or partial wood/panel/stone cladding
  • plastering
  • 2x mesh adhesion
  • fiberglass mesh
  • 10 cm thermal insulation
  • 12mm OSB building board
  • steel frame Aday C140
  • 10 cm sprayed polyurethane insulation
  • vapor barrier foil
  • air gap
  • 1 layer of drywall

Ceiling layer structure (from top to bottom):  

  • 25 cm glass wool insulation
  • suspended ceiling structure
  • vapor barrier foil
  • air gap
  • 1 layer of drywall

Roof covering layer structure (from outside to inside): 

  • IKO rectangular roof shingles in 6 colors or tile sheet Optional other covering
  • Optional: Roof sheet, concrete tile
  • 15 mm OSB
  • vapor barrier foil
  • roof plumbing works, gutter, with 2 downspouts
  • painted steel gutter system in 3 colors (Brown RAL 8017, Red RAL 3009, Anthracite
  • RAL 7016)

 

Floor layer structure:  

  • 10 cm insulation
  • 6 cm Estrich concrete

 

Other: 

  • standard-sized white Aluplast 4000 windows, based on standard dimensions.
  • plastic, white entrance door
  • water network installation inside the building: sink connection, dishwasher
  • connection, 2x washbasin connection, 2x toilet connection, 1 shower connection / or
  • bathtub connection
  • Basic electrical wiring (conduit installation) up to 40 endpoints, wires, fittings (switch,
  • socket, light fixture) and electrical cabinet not included
  • "H" tariff system installation and associated electrical cabinet
  • heating – "H" tariff system inverter air conditioners (based on brand and quantity
  • agreement, price quote modification item)

Debris removal: 

  • In case of external finish condition: 4 cubic meters
  • In case of raised heating condition: 6 cubic meters. Only construction waste may be
  • placed in the containers. For any other waste disposal, the removal of the container is
  • the responsibility of the client.

The price does not include: 

  • costs of utility connections
  • earthworks - concrete base
  • grounding - interior doors and their installation
  • window sills
  • interior painting, plastering
  • coverings - sanitary ware
  • electrical wiring above 40 connections, fuses, planned switches, sockets
  • multi-colored exterior facade painting
  • chimneys - boiler(s)

Additional optional technical contents: 

  • non-standard sized window, in any color – based on a custom quote
  • selectable stone, wood, metal facade cladding – based on a custom quote
  • expanded electrical network installation with wiring, electrical cabinet
  • painting, plastering in multiple layers
  • electric water heater boiler